MetriBeacon
Menu

Measurements, counters and summaries

Use current measurements or running counters and understand chart summaries.

On this page

What you need

A numerical series with a known unit.

How to do it

  1. Choose Gauge for a changing value such as temperature, or Counter for a running total such as bytes transferred.
  2. Send readings with their actual measurement times. Numerical readings in the same series need at least one second between them.
  3. Open history and choose original values or an available summary resolution. Check whether the chart shows a mean, minimum, maximum, last value or counter rate.

Good to know

Summaries combine readings in a time interval. Means are weighted by the number of original readings, so a lightly sampled interval does not count as much as a heavily sampled one.

Counter resets are handled separately from increases. Missing readings remain gaps; they do not become zeros.

If something goes wrong

For an unexpected spike or rate, check the clock, unit and original readings before changing chart settings.